ORIGINAL ARTICLE
Year : 2016  |  Volume : 3  |  Issue : 2  |  Page : 60-65

Assessment of peak kilovoltage accuracy in ten selected X-ray centers in Lagos metropolis, South-Western Nigeria: A quality control test to determine energy output accuracy of an X-ray generator


Department of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi Araba, Lagos, Nigeria

Correspondence Address:
Akintayo Daniel Omojola
Department of Radiation Biology, Radiotherapy, Radiodiagnosis and Radiography, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2394-2010.184231

Rights and Permissions

Background: Most X-ray centers recruited for this study admitted that there have been no maintenance checks on the energy output accuracy of their X-ray machines. Most centers complained of recurrent machine breakdown due to poor power supply, while others pointed out that X-ray machine age could be a contributory factor to poor image quality. Aim and Objectives: To determine peak kilovoltage (kVp) accuracy of individual X-ray unit and to compare their values with recommended standards and to further establish if machine age has a significant effect on mean kVp accuracy. Materials and Methods: One dedicated conventional X-ray unit in each of the ten diagnostic centers was used for this study denoted as D 1−D 10 . kVp was measured using a noninvasive Unfors ThinX RAD kVp meter. The kVp accuracy test was carried out by positioning the Unfors ThinX RAD kVp meter at the center of the beam axis of the patient's couch at a focus to image distance of 100 cm. The X-ray machine technical factors were varied by selecting tube potential within the range of 50−120 kVp at a fixed tube current of 20 mA. Data analysis value was done using GraphPad Prism version 5.0 statistics software (GraphPad Software, Inc., San Diego, California, USA). Results: The kVp accuracy test for X-ray units D 1 , D 2 , D 5 , D 6 , D 7 , and D 8 were within an acceptable limit of ±5% at all selected tube potential from 50 to 120 kVp, X-ray units D 2 and D 6 showed accurate compliance at much lower kVp accuracy values. X-ray units D 3 and D 10 were above ±5% accuracy limit at all selected kVp tube potential. No statistically significant differences exist between machine age and mean kVp accuracy (P = 0.770). Conclusion: One-fourth of the total kVp accuracy results were above ±5% limit. Old X-ray machine had higher chances of failed kVp accuracy. Traces of failed test were also noticed in X-ray machines below 5 years.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2704    
    Printed46    
    Emailed0    
    PDF Downloaded264    
    Comments [Add]    

Recommend this journal